Cold-Chain & Refrigerated Truck Batteries

A refrigerated truck carries two electrical loads that need two different batteries: the engine's cold-start burst and the reefer unit's continuous, hours-long draw. Confusing the two strands drivers mid-route.

Key Takeaways

  1. Two loads demand two battery types — a starting (SLI) battery for the 850–1100+ CCA crank, and a separate deep-cycle bank for the reefer's continuous draw.
  2. Never run the reefer off the starting battery — a 25 A unit draws ~200 Ah over 8 hours and deep-discharges the plates; the truck starts fine on the lot, then strands the driver after an overnight stop.
  3. Isolation is not enough — a basic isolator only blocks reverse current and drops ~0.3–0.7 V; a DC-DC charger also applies a proper multi-stage charge the cycled auxiliary bank needs.
  4. Size the bank to the draw — a 25 A/8-hour duty needs ~200 Ah usable, or ~400 Ah of bank at the 50% depth-of-discharge limit.

Why a Reefer Needs Two Systems

The two loads are fundamentally different. The engine needs a short, high-current burst — 850–1100+ CCA for a large diesel — delivered in seconds. The refrigeration unit needs a modest but continuous current for hours while the truck is parked overnight or loading.

A starting battery is built for the first job: thin plates that deliver high current briefly. Drawing that battery down continuously for hours — as a reefer does — discharges it deeply and permanently damages the plates. The result is a vehicle that starts fine at the depot but won't crank the next morning. The fix is a separate deep-cycle or AGM bank dedicated to the reefer, with the two banks isolated so neither can drag the other down.

Recommended Specifications

LoadBattery typeKey figure
Engine startingStarting (SLI) battery850–1100+ CCA
Refrigeration unitDeep-cycle or AGM auxiliary bank~200 Ah usable per 25 A / 8 h
System voltage12V or 24V per vehicleMatched pair rule applies
Auxiliary depth of discharge~50% limit~400 Ah bank for 200 Ah usable

Figures are representative. Exact CCA, bank capacity and runtime depend on the reefer unit's specified draw — contact us for a datasheet matched to your fleet.

Product Lines for Cold-Chain Fleets

Starting Batteries (N150/N200 / DIN)

High-CCA starting batteries for the tractor — JIS 145G51/190H52 or DIN 58827/60038.

View JIS Heavy-Duty →

Auxiliary & AGM Banks

Deep-cycle and AGM for the reefer's continuous draw — sealed, maintenance-free.

View Fleet & AGM →

Frequently Asked Questions

What battery does a refrigerated truck need?

A refrigerated truck needs two separate systems: a starting battery with 850–1100+ CCA for the engine, and a deep-cycle or AGM auxiliary bank for the refrigeration unit. One battery cannot serve both jobs.

Can I run the reefer off the starting battery?

No. A 25 A refrigeration unit draws roughly 200 Ah over 8 hours and will deep-discharge a starting battery, damaging it and risking a no-start mid-route. Use a separate auxiliary bank.

What type of battery is best for a reefer unit?

Deep-cycle or AGM batteries are best for the reefer's continuous draw — they tolerate repeated discharge to about 50% without the plate damage a starting battery suffers.

How do I size a reefer auxiliary bank?

Size it to the reefer's continuous current draw and required runtime. A 25 A unit over 8 hours needs about 200 Ah usable — roughly 400 Ah of bank at the 50% depth-of-discharge limit. Confirm the unit's draw from its specification.